Fluorescent lighting flicker frequency measured against headache and eyestrain incidence in office workers

Wilkins AJ, Nimmo-Smith I, Slater AI, Bedocs L (1989) · Lighting Research & Technology

In a double-blind crossover trial, the weekly incidence of headaches and eyestrain was more than halved when fluorescent lamps were driven by high-frequency electronic ballasts (about 32 kHz, under 7% modulation) rather than conventional 100 Hz ballasts with 43 to 49% modulation depth.

What they studied

Office workers in a UK office building, double-blind crossover

What they found

In a double-blind crossover trial, the weekly incidence of headaches and eyestrain was more than halved when fluorescent lamps were driven by high-frequency electronic ballasts (about 32 kHz, under 7% modulation) rather than conventional 100 Hz ballasts with 43 to 49% modulation depth.

What it does not establish

This entry reports the study. It is not a statement about any building Sage Co. designs or constructs.

Source

  • Wilkins AJ, Nimmo-Smith I, Slater AI, Bedocs L (1989). Fluorescent lighting flicker frequency measured against headache and eyestrain incidence in office workers · Lighting Research & Technology · Read at the source