[ESTABLISHED]Established
Lead concentrations measured in tap water after a change in corrosion control
Repeated sampling at a single residence reported elevated tap-water lead concentrations following a source-water change made without corrosion-control treatment, and a decline after treatment was restored.
How to read this
This library reports what studies found. An entry describes a study's design, its findings in its own terms, and its limits. Nothing here is a claim about what a Sage Co. home does, delivers, or prevents.
Last reviewed August 30, 2026.
What they studied
- A longitudinal sampling investigation at one house in Flint, Michigan, with sequential and repeated tap sampling over roughly two years.
- Sampling spanned the period before, during, and after the municipal source-water change that was made without orthophosphate corrosion-control treatment.
- Analyses characterized lead concentrations by sample sequence to distinguish plumbing sources.
What they found
- The authors reported very high lead concentrations in tap samples during the period without corrosion-control treatment, including samples far above regulatory action levels.
- They reported that concentrations declined after the source water was switched back and corrosion-control treatment was reinstated, though not immediately.
- Sequential sampling was reported to attribute much of the lead to the service line and premise plumbing rather than the distribution main alone.
What this study does not establish
- A single residence in one city; the magnitudes reported are specific to that plumbing and that water chemistry.
- Findings concern water chemistry and plumbing materials, not occupant health outcomes measured in this study.
- Results do not transfer to any other water system without local sampling.
- This entry reports the study. It is not a statement about any building Sage Co. designs or constructs.
Source
Pieper KJ, Tang M, Edwards MA (2017). Flint water crisis caused by interrupted corrosion control: investigating 'ground zero' home. Environmental Science & Technology 51(4):2007–2014.
leadcorrosion controlpremise plumbingsampling
Elsewhere under Water Quality