Dust fungi and endotoxin measured against respiratory symptoms in a water-damaged office building
Park J-H, Cox-Ganser JM, Rao C, Kreiss K (2006) · Indoor Air 16(3):192–203
In a study of occupants of one water-damaged office building, both fungal and endotoxin measures in dust were reported in dose-response association with respiratory symptoms, with an interaction between them.
What they studied
Eight hundred eighty-eight occupants of a water-damaged office building.
Floor and chair dust sampling analyzed for fungi, ergosterol, and endotoxin.
Questionnaire assessment of respiratory symptoms, analyzed by exposure quartile.
What they found
Dose-response relationships were reported for both endotoxin and fungal measures with respiratory symptoms.
The authors reported that endotoxin modified the association between fungi and symptoms.
Associations were reported to be stronger when both exposures were considered together.
What it does not establish
Cross-sectional study of a single building.
Dust measures are proxies for inhalation exposure.
Self-reported symptoms; no clinical diagnosis endpoint.
This entry reports the study. It is not a statement about any building Sage Co. designs or constructs.
Source
- Park J-H, Cox-Ganser JM, Rao C, Kreiss K (2006). Fungal and endotoxin measurements in dust associated with respiratory symptoms in a water-damaged office building · Indoor Air 16(3):192–203 · Read at the source
Last reviewed August 30, 2026.
Related reading
- Understanding Ventilation in Hot-Humid Climates
- LBNL Indoor Environment Group — IAQ Science
- NIST Indoor Air Quality and Ventilation Group
- ANSI/ASHRAE Standard 62.2 — Ventilation and Acceptable Indoor Air Quality in Residential Buildings
- ANSI/ASHRAE Standard 241 — Control of Infectious Aerosols
- EPA Indoor airPLUS Construction Specifications